{"product_id":"godiag-bmw-cas1-cas2-mech-key-test-platform-cas-and-key-synchronization-tool-with-solder-free-matching-cas-data-read-write-and-programming","title":"GODIAG BMW CAS1 CAS2 Mech-Key Test Platform, CAS and Key Synchronization Tool with Solder-Free Matching, CAS Data Read\/Write and Programming","description":"\u003ch3\u003eGODIAG BMW CAS1 CAS2 Mech-Key Test Platform, CAS and Key Synchronization Tool with Solder-Free Matching, CAS Data Read\/Write and Programming\u003c\/h3\u003e\n\u003cp\u003eGODIAG BMW CAS1\/CAS2 Mech-Key Test Platform is a dedicated device developed for BMW locksmiths, maintenance engineers and CAS1 \/ CAS2 programming engineers. It can cooperate with the key programming devices like xhorse Key Tool Plus Pad \/ xhorse vvdi 2 \/ bmw vvdi bim tool \/ Autel im608 \/ CGDI BMW \/ Lonsdor devices, OBDSTAR devices, etc., to perform all key lost matching or key addition operations. Please note that this product is only suitable for mechanical keys.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249385858.jpg?v=1780674294\"\u003e\u003c\/p\u003e\n\u003ch5\u003eFeatures:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDetect CAS and key synchronization\u003c\/li\u003e\n\u003cli\u003eSolder-free matching CAS1\/CAS2 mechanical key\u003c\/li\u003e\n\u003cli\u003eCAS data reading, writing and programming\u003c\/li\u003e\n\u003cli\u003eAll keys lost \/adding keys matching\u003c\/li\u003e\n\u003cli\u003eCAS key data backup\u003c\/li\u003e\n\u003cli\u003eCAS module function judgment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cstrong\u003eFunctions\u003c\/strong\u003e:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eCheck if the CAS1\/CAS2 module and mechanical keys are synchronized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249385173.jpg?v=1780674651\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCooperate with the key programming devices like xhorse Key Tool Plus Pad \/ xhorse vvdi 2 \/ bmw vvdi bim tool \/ Autel im608 \/ CGDI BMW \/ Lonsdor devices, OBDSTAR devices, etc., to perform all key lost matching or key addition operations.\u003c\/li\u003e\n\u003cli\u003eCAS1\/CAS2 module diagnostics\u003c\/li\u003e\n\u003cli\u003eCAS1 \/ CAS2 module programming\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSynchronous detection of module and key:\u003c\/h5\u003e\n\u003cp\u003eCheck whether the CAS2 module and mechanical key can be synchronized:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Connect the CAS2 module according to the connection diagram\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Put the key into the key sensing area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e Connect the power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e Press the start switch (press the start switch once to turn on the CAS power and automatically detect whether the key and CAS are synchronized, press it again to turn off the CAS power and turn off the detection).when the detection start switch is pressed, the Power indicator light will light up. If the key is synchronized with CAS2, the CAS module key induction coil indicator light will flash regularly. If it is an unsynchronized key, the key induction coil indicator light will only flash quickly for 2 seconds. (If the key is synchronized with the CAS module, the IMMO synchronization detection indicator light will light up and the internal buzzer of the machine will sound. If the key is not synchronized with the CAS module, the IMMO synchronization detection indicator light will not light up and the internal buzzer of the machine will not sound.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Press and hold the analog start\/stop button, the IMMO synchronization detection indicator light will go out after 3 seconds. The INDUC sensor indicator light also goes out. After releasing, the IMMO synchronization detection indicator light will light up. The INDUC sensor indicator light flashes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCAS1 module and key synchronization detection:\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249385025.jpg?v=1780675286\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the device according to the connection diagram. Please use 12V 2.5A for power supply, otherwise the CAS1 module cannot be driven. (Do not connect the CAS2 module)\u003c\/li\u003e\n\u003cli\u003ePress the start switch (you can see the START-STOP indicator light on the CAS lights up)\u003c\/li\u003e\n\u003cli\u003eInsert the key into CAS1\u003c\/li\u003e\n\u003cli\u003ePress the CAS1 key. If the key is synchronized with the CAS1 module, the CAS1 key will be locked. It will automatically exits if the key is not synchronized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCAS2 mechanical key module key programming and module programming identification diagnostic connection demonstration:\u003c\/h5\u003e\n\u003cp\u003eThe following uses xhorse VVDI2 device to perform BMW CAS2 mechanical key programming and matching operations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the CAS2 mechanical key module and key programming diagnostic equipment according to the connection diagram. Press the start button to provide power to CAS2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249399612.jpg?v=1780675444\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \"key learn-CAS\/EWS Information-Connect-- Read EEPROM\". (Note: Take away the key and do not perform synchronization detection between the key and the CAS2 module before connecting to read data. Just press the start button to power the CAS module. If the CAS module detects a synchronized key, then the connected device cannot read the data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249391003.jpg?v=1780675943\"\u003e\u003c\/p\u003e\n\u003cp\u003eSave to File...\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249397964.jpg?v=1780676034\"\u003e\u003c\/p\u003e\n\u003cp\u003eIf you want to read the CAS mileage or modify the CAS mileage, please operate the corresponding menu\"Read KM\".\u003cbr\u003eIt can also read CAS code-DME.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249396375.jpg?v=1780676471\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey programming steps: select \"key learn-CAS Key Learn -Connect\" , select \"Get Key Info\" and \"Save Key Info.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249405551_1.jpg?v=1780676682\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect an unused key position, be sure to select the \"prepare dealer key with programmer\" menu, and use the VVDI2 key programmer to generate the key. If the key is placed in the key sensing area of the GODIAG BMW CAS1\/CAS2 Mech-Key Test Platform, the dealer key will not be generated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249401612.jpg?v=1780676783\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249402801.jpg?v=1780676835\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAfter programming the dealer key, place the key into the Godiag BMW CAS1\/CAS2 Mech-Key Test Platform sensor port for testing. For test steps, please refer to module and key synchronization detection.\u003cbr\u003eIf the new key detection is out of sync, please synchronize CAS and DME or synchronize CAS and ELV. Reconnect the device and module and press the button'Check the start switch' If the IMMO light cannot light up, enter the VVDI2 menu \"Key Learn-CAS\/EWS Information-Connect-Synch DME-CAS or Synch CAS-ELV\" for synchronization operation. (When performing synchronization, the key must be placed in the key sensing programming area of the VVDI2 device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249417080.jpg?v=1780676886\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249412671.jpg?v=1780676927\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch5\u003eThe following uses the xhorse vvdi2 device to perform the BMW CAS1 key programming and matching operation:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the CAS1 module and the key programming diagnostic device according to the connection diagram. Press the START switch on the Godiag BMW CAS1\/CAS2 Mech-Key Test Platform and the POW indicator light will light up, indicating that the test platform has output power. The indicator light on the CAS1 mode will also light up. (Please use 12V 2.5A power supply, otherwise it will not be able to drive the CAS1 module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249418566.jpg?v=1780677230\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \"key learn-CAS\/EWS Information-Connect-- Read EEPROM\". (Be careful not to insert the key. If the data cannot be read, please reconnect and turn on the platform power.) (Note: Do not perform a synchronization test between the key and the CAS1 module, otherwise the connection or data reading will not be possible. If a synchronization test is performed, please disconnect the power supply and reconnect the device and CAS module.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249421801_1.jpg?v=1780677382\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eSave to File...\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249422062.jpg?v=1780677436\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIf you want to read the CAS mileage or modify the CAS mileage, please operate the corresponding menu \"Read KM\". It can also read CAS code-DME.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249427318.jpg?v=1780677565\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey programming steps: select \"key learn-CAS Key Learn-Connect\". Select \"Get Key Info\" and \"Save Key Info\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249431054.jpg?v=1780677621\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect an unused key position, be sure to select the \"prepare dealer key with programmer\" menu, and use the VVDI2 key programmer to generate the key. (Because the CAS1 module key identification socket or GODIAG BMW CAS1\/CAS2 Mech-Key Test Platform key sensor cannot generate dealer keys.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249433808.jpg?v=1780677733\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249434074.jpg?v=1780677773\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAfter the dealer key is successfully programmed, place the key into the CAS1 module key module socket for testing. For test steps, please refer to the CAS1 module and key synchronization detection steps.\u003cbr\u003eIf the IMMO light cannot light up, enter the VVDI2 menu \"Key Learn-CAS\/EWS Information-Connect-Synch DME-CAS or Synch CAS-ELV\" for synchronization. (When performing synchronization, the key must be placed in the VVDI2 device key sensing area.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/7418\/2488\/files\/24010417044249434313.jpg?v=1780677822\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch5\u003eIncludes:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e1pc x GODIAG BMW CAS1\/CAS2 Mech-Key Test Platform.\u003c\/li\u003e\n\u003cli\u003e1pc x OBD2 to DB25 Cable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GODIAG","offers":[{"title":"Default Title","offer_id":62058542727538,"sku":"GDG-BMW-CAS1-CAS2","price":59.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0951\/0596\/files\/GDG-BMW-CAS1-CAS2__1.jpg?v=1784901926","url":"https:\/\/www.locksmithkeyless.com\/products\/godiag-bmw-cas1-cas2-mech-key-test-platform-cas-and-key-synchronization-tool-with-solder-free-matching-cas-data-read-write-and-programming","provider":"Locksmith Keyless","version":"1.0","type":"link"}