Altronix - EFLOW102N16D - Power Supply Charger with 16 PTC Protected Outputs Class 2 Power-Limited - BC300 Enclosure
Couldn't load pickup availability
Delivery and Shipping
Delivery and Shipping
All orders are shipped between 24 hours or less Monday through Friday from 9:00 am to 6:00pm. Orders placed after 4 p.m. EST will be shipped next business day.Â
Learn more
Description
Description
Altronix - EFLOW102N16D - Power Supply Charger with 16 PTC Protected Outputs Class 2 Power-Limited - BC300 Enclosure
Ideal for a multitude of purposes, including CCTV, Fire Alarm and POIP. A leading global provider of power and transmission technologies for professional security system applications, Altronix develops innovative solutions that integrate disparate infrastructure and maximize overall performance and efficiency.
Altronix Power Supplies are ideal for a multitude of purposes, including:
- General Use
- CCTV
- Fire Alarm
- POIP
Input:
- 120VAC, 60Hz, 3.5A.
- Input fuse: 5A/250V.
Output:
- Sixteen (16) Class 2 power-limited PTC protected outputs (auto-resettable).
- Outputs are rated @ 2A.
- 12VDC @ 10.0A supply current.
- Auxiliary Class 2 Power-Limited output rated @ 1A (unswitched).
- Overvoltage Protection.
Supervision:
- AC fail supervision (form "C" contacts).
- Notification trigger is selectable for 30 seconds (factory set) or 2 hours.
- Battery fail and presence supervision (form "C" contacts).
- Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% (depending on the power supply). Prevents deep battery discharge.
Fire Alarm Disconnect:
- Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.
Battery Backup:
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.
Temperature:
- Operating: 0° C to 49° C (32° F to 120° F).
- Storage: - 20° C to 70° C ( - 4° F to 158° F).
- Relative Humidity 85% +/- 5%.
- BTU/Hr. (approx.): 61 BTU/Hr.
- System AC input VA requirement: 420VA.
Visual Indicators:
- Green AC Power LED indicates 120VAC present.
- AC input and DC output LED indicators.
Additional Features:
- Short circuit and overload protection.
- Unit is complete with power supply, enclosure, battery leads and cam lock.
Enclosure:
- Wall mount enclosure for indoor use.
- Accommodates up to one (1) 12VDC/7AH Batteries.
- Dimensions 13"W x 13.5"H x 3.25"D (330 mm W x 343 mm H x 83 mm D).
- 1/2" and 3/4" combination knockouts.
Download:
Reviews
Reviews
Q&A
Q&A
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.